The BICSI DCDC-002 certification exam is ideal for professionals who are looking to advance their careers in the field of data center design. This exam is designed to test the knowledge, skills, and abilities of professionals who are involved in the design, construction, and operation of data centers. The DCDC certification is recognized globally as a mark of excellence in the field of data center design, and can help professionals to stand out in a competitive job market.
NEW QUESTION # 32
where is the storage room located?
- A. Near Backup Generator
- B. next door to computing area
- C. outermost point of Data Centre
- D. away from computer room, adjacent to equipment entrance at data center
- E. All
Answer: D
NEW QUESTION # 33
what can take up to40 percent of overall space in the equipment area?
- A. principal loads
- B. electrical equipments
- C. redistribution systems
- D. all of above
- E. computer
- F. circulation and support equipment
Answer: F
Explanation:
Explanation
NEW QUESTION # 34
What is the clearance required between the cold aisle and the CRAC unit?
- A. 6 feet
- B. 2 feet
- C. 4 feet
- D. 8 feet
Answer: D
NEW QUESTION # 35
What are the recommended grounding requirements for DC power systems?
- A. Single point ground
- B. None of the above
- C. Distributed ground
- D. Multiple point ground
Answer: A
NEW QUESTION # 36
What type of power utility service is desired?
- A. Direct Current (DC) utility service
- B. Underground or overhead utility service
- C. Overhead utility service
- D. Renewable energy-based utility service
Answer: B
NEW QUESTION # 37
What is the minimum separation distance of underground telecommunications and utility cabling in same route?
- A. 6 feet minimum along entire route
- B. 2 feet minimum along entire route
- C. none of the above
- D. no need for separation as long as they are enclosed in different conduit systems.
Answer: A
NEW QUESTION # 38
what are the two rooms that may require 2 exits?
- A. Mechanical Room and Electrical
- B. the electrical Room and battery room
- C. Equipment Room and Security Rooms
- D. Computing rooms And Storage rooms
- E. Water Supply Rooms
Answer: B
Explanation:
Explanation
NEW QUESTION # 39
What is the recommended level of redundancy for a critical power system in a Tier III data center?
- A. 3N
- B. 2N
- C. N
- D. N+1
- E. 2N+1
Answer: D
NEW QUESTION # 40
What is the ASHRAE TC 9.9 recommended range for static pressure in a data center?
- A. 0.15-0.2 inches water gauge
- B. 0.05-0.1 inches water gauge
- C. 0.01-0.05 inches water gauge
- D. 0.1-0.15 inches water gauge
Answer: C
NEW QUESTION # 41
What type of slope is considered too extreme for a data center site?
- A. 10%
- B. 15%
- C. 20%
- D. 5%
Answer: B
NEW QUESTION # 42
What is the most common type of automatic transfer switch?
- A. Soft load transition
- B. Open transition
- C. Delayed transition
- D. Closed transition
Answer: B
NEW QUESTION # 43
What electrical service feed options are there for a data center?
- A. Dual Entrance/Dual Pathway
- B. Single Entrance/Dual Pathway
- C. Single Entrance/Single Pathway
- D. All of the above
Answer: D
NEW QUESTION # 44
What is the formula to find the maximum allowable cable depth in a non-solid bottom cable tray?
- A. H = 50/1 + (L * 0.0007)
- B. H = 150/1 + (L * 0.0007)
- C. H = 200/1 + (L * 0.0007)
- D. H = 100/1 + (L * 0.0007)
Answer: B
NEW QUESTION # 45
What is the minimum access floor to ceiling height recommended?
- A. 8 feet minimum
- B. 10 feet minimum
- C. 11ft minimum
- D. 9 feet minimum
Answer: B
NEW QUESTION # 46
What is the function of an emergency generator?
- A. back up office lighting
- B. supply power to the restrooms during a utility outage
- C. all of the above
- D. provide backup power to IT equipment only
Answer: C
NEW QUESTION # 47
......
The DCDC exam evaluates the candidate's understanding of critical elements such as space planning, electrical systems, HVAC systems, security systems, and networking. It requires a solid understanding of industry standards, codes, and guidelines for data center design and operations.