NEW QUESTION 47
Which of the following statements about the up-and-down about PON technology is correct?

  • A. PON technology data downlink uses broadcast
  • B. PON technology data uplink uses broadcast
  • C. PON technology downlink adopted wavelength is 1310nm.
  • D. PON technology uplink adopted wavelength is 1490nm

Answer: A

 

NEW QUESTION 48
The following are the operations that should be described before the power-on of the communication device. What are the correct descriptions? (Multiple Choice)

  • A. All power switches of the powered device are disconnected
  • B. Check the electrical connection is firm and reliable
  • C. The output switch of the power supply device is disconnected and the output voltage is normal.
  • D. Measuring no short circuit inside the powered device
  • E. Measure the power supply circuit without short circuit between each other and the ground
  • F. Rated output current meets the needs of powered devices

Answer: A,B,C,D,E,F

 

NEW QUESTION 49
What are the items of EHS self-management? (Multiple choice)

  • A. Preparation before work
  • B. Pre-work inspection
  • C. Inspection in the operation

Answer: A,B,C

 

NEW QUESTION 50
About the requirements that OceanStor 18000 series high-end storage requirements for the environment, which is wrong?

  • A. It is recommended to use a high efficiency filter to filter the air entering the air center of the data center.
  • B. It is recommended to adopt the layout of hot and cold air duct isolation.
  • C. Can work at various altitudes
  • D. There are certain requirements for vibration and shock

Answer: C

 

NEW QUESTION 51
Which is the role of the positioning rope?

  • A. Fix the material
  • B. Use when climbing the tower
  • C. Fix the body for working easily

Answer: C

 

NEW QUESTION 52
All new partners must first interview the corresponding project manager and product line technical leader before entering the area, and sign the safety production commitment letter, the network safety behavior red line commitment letter, and receive the supervision certificate before entering the area, new employees do not allow to operate the existing network equipment.

  • A. False
  • B. True

Answer: B

 

NEW QUESTION 53
Unpack and inspect the goods delivered to the site, check the total number of goods according to the packing list number attached to each box, and check whether the appearance of each box is intact.

  • A. False
  • B. True

Answer: B

 

NEW QUESTION 54
About V3 storage product BBU redundancy configuration, which of the following is incorrect?

  • A. 5500V3, BBU1+1
  • B. 5600V3, BBU2+1
  • C. 5800V3, BBU2+1
  • D. 6800V3, BBU3+1

Answer: B

 

NEW QUESTION 55
Vehicle safety does not need to be checked before each drive.

  • A. False
  • B. True

Answer: A

 

NEW QUESTION 56
RH5885H V3 PCIE supports hot plugging.

  • A. False
  • B. True

Answer: B

 

NEW QUESTION 57
When the pigtail cabinet is placed outside, it can be placed directly without protective measures.

  • A. False
  • B. True

Answer: A

 

NEW QUESTION 58
The signal cable can be placed on the heat dissipation mesh of the cabinet.

  • A. False
  • B. True

Answer: A

 

NEW QUESTION 59
Which of the following is the key basis for the division of operational responsibility for the operation of the equipment power bus to the client room power supply?

  • A. Supervision instructions
  • B. The results of the consultation meeting
  • C. Customer requirements
  • D. Contract Engineering Interface

Answer: D

 

NEW QUESTION 60
In FTTx optical access scenarios, what kinds of indoor cabinets does it have? (Multiple Choice)

  • A. N66E-22 cabinet
  • B. N63E-22 cabinet
  • C. N68E-28 cabinet
  • D. N68E-22 cabinet

Answer: A,B

 

NEW QUESTION 61
Regarding the MA5800 frame type equipment, the equipment installation environment quality standards, what are the correct statements? (Multiple Choice)

  • A. AC power supply related parameters are in line with the long-term safe operation of the equipment. The equipment room AC power system should have a lightning protection unit, and the lightning protection unit should be grounded reliably.
  • B. Customer's PGND cable, GND cable of primary power supply, wire diameter and power supply mode of a 48V cable to PDF or distribution box, subject to engineering design documents and company shipments, to meet equipment operation and capacity expansion requirements.
  • C. The AC protection ground of the AC power supply should be reliably connected to the AC protection ground. The GND grounding and PGND grounding provided by the customer must be connected to the same grounding body.
  • D. No fire and anti-static measures are required in the equipment room.

Answer: A,B,C

 